| Availability: | |
|---|---|
| Quantity: | |
True online double conversion
Microprocessor control ensures high reliability
Input power factor correction
Output power factor can reach 0.8
Wide AC input range (110V~300V)
Efficient variable frequency conversion mode
ECO mode provides energy saving effect (only for 1~3k models) compatible with generators
Long-term model charging current up to 6A
| Model | CT00111RL | CT00211RL | CT00311RL | CT00611RL | CT01011RL |
| Capacity | 1000VA/800W | 2000VA/1600W | 3000VA/2400W | 6000VA/4800W | 10000VA/8000W |
| Phase | Single Phase | Input, Single Phase Output | Single Phase Input, Single Phase Output | Single Phase Input, Single Phase Output | Single Phase Input, Single Phase Output |
| Input Voltage | 200/208/220/230/240VAC | 200/208/220/230/240VAC | 200/208/220/230/240VAC | 208/220/230/240VAC | 208/220/230/240VAC |
| Input Voltage Range | 110-300VAC@50% load; 160-300VAC@100% load | 110-300VAC@50% load; 160-300VAC@100% load | 110-300VAC@50% load; 160-300VAC@100% load | 110-300VAC@50% load; 176-300VAC@100% load | 110-300VAC@50% load; 176-300VAC@100% load |
| Frequency Range | 40~70Hz | 40~70Hz | 40~70Hz | 46Hz~54Hz or 56Hz~64Hz | 46Hz~54Hz or 56Hz~64Hz |
| Power Factor | - | - | - | ≥0.99@100% load | ≥0.99@100% load |
| Output Voltage | 200*/208*/220/230/240VAC | 200*/208*/220/230/240VAC | 200*/208*/220/230/240VAC | 208**/220/230/240VAC | 208**/220/230/240VAC |
| Voltage Regulation | ±1% | ±1% | ±1% | ±1% | ±1% |
| Frequency Range (Synchronization Range) | 47~53Hz or 57~63Hz | 47~53Hz or 57~63Hz | 47~53Hz or 57~63Hz | 46~54Hz or 56~64Hz | 46~54Hz or 56~64Hz |
| Overload (Utility Mode) | 105%-110%: 10 minutes; 110%-130%: 1 minute; >130%: 3 seconds | 105%-110%: 10 minutes; 110%-130%: 1 minute; >130%: 3 seconds | 105%-110%: 10 minutes; 110%-130%: 1 minute; >130%: 3 seconds | 100%-110%: 30 minutes; 110%-130%: 5 minutes; >130%: 10 seconds | 100%-110%: 30 minutes; 110%-130%: 5 minutes; >130%: 10 seconds |
| Overload (Battery Mode) | 105%-110%: 10 minutes; 110%-130%: 1 minute; >130%: 3 seconds | 105%-110%: 10 minutes; 110%-130%: 1 minute; >130%: 3 seconds | 105%-110%: 10 minutes; 110%-130%: 1 minute; >130%: 3 seconds | 100%-110%: 3 minutes; 110%-130%: 30 seconds; >130%: 10 seconds | 100%-110%: 3 minutes; 110%-130%: 30 seconds; >130%: 10 seconds |
| Harmonic Distortion | ≤3% (Linear Load); ≤6% (Non-linear Load) | ≤3% (Linear Load); ≤6% (Non-linear Load) | ≤3% (Linear Load); ≤6% (Non-linear Load) | ≤3% (Linear Load); ≤5% (Non-linear Load) | ≤3% (Linear Load); ≤5% (Non-linear Load) |
| Transfer Time (Utility to Battery) | 0ms | 0ms | 0ms | 0ms | 0ms |
| Transfer Time (Inverter to Bypass) | - | - | 4ms (Standard Conditions) | - | 0ms |
| Efficiency (Utility Mode) | 88% | 88% | 89% | 90% | 92% 93% |
| Efficiency (Battery Mode) | 83% | 83% | 87% | 88% | 90% 91% |
| Battery (Standard Machine) | 12V/7Ah or 12V/9Ah | 12V/7Ah or 12V/9Ah | 12V/7Ah or 12V/9Ah | - | - |
| Battery Quantity (Standard Machine) | 2 | 2 | 4 | 6 | - |
| Battery (Long Effect Machine) | Varies by Application | Varies by Application | Varies by Application | Varies by Application | Varies by Application |
| Battery Quantity (Long Effect Machine) | 2, 3, 4, 6, 8 (6, 8 for 6-10kVA) | 2, 3, 4, 6, 8 (6, 8 for 6-10kVA) | 2, 3, 4, 6, 8 (6, 8 for 6-10kVA) | 16-20 | 16-20 |
| Dimensions (Standard Machine) | 310x438x88 mm | 310x438x88 mm | 410x438x88 mm | 630x438x88 mm | - |
| Weight (Standard Machine) | 12 kg | 12 kg | 19 kg | 21.3 kg | - |
| Dimensions (Long Effect Machine) | 310x438x88 mm | 310x438x88 mm | 410x438x88 mm | 410x438x88 mm | 530x438x88 mm 580x438x133 mm |
| Weight (Long Effect Machine) | 9 kg | 9 kg | 8.5 kg | 12 kg | 13 kg 17 kg |
| Operating Environment | Temperature and Humidity | 20-90%RH @ 0~40℃ (No Condensation) | 20-90%RH @ 0~40℃ (No Condensation) | 20-90%RH @ 0~40℃ (No Condensation) | 0-95%RH @ 0-50℃ (No Condensation) |
| Altitude | <1000m | <1000m | <1000m | <1000m | <1000m |
| Noise Level | <50dB at 1 meter | <50dB at 1 meter | <50dB at 1 meter | <50dB at 1 meter | <55dB at 1 meter <58dB at 1 meter |
| Control and Management | Intelligent RS-232 or USB | Supported for Windows 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC | Supported for Windows 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC | Supported for Windows 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC | Supported for Windows 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC |
| Optional SNMP | Support for power management by SNMP manager and network browser | Support for power management by SNMP manager and network browser | Support for power management by SNMP manager and network browser | Support for power management by SNMP manager and network browser | Support for power management by SNMP manager and network browser |